OPTIONS NODATE NONUMBER PAGESIZE=66 LINESIZE=72; ********************************; *** GAUGE CAPABILITY STUDY ***; ********************************; DATA RRS; DO PART = 1 TO 20; DO MSRMNT = 1 TO 2; INPUT RESPONSE @@; OUTPUT; END; END; CARDS; 21 20 24 23 20 21 27 27 19 18 23 21 22 21 19 17 24 23 25 23 21 20 18 19 23 25 24 24 29 30 26 26 20 20 19 21 25 26 19 19 ; PROC GLM DATA=RRS; CLASS PART ; MODEL RESPONSE = PART / SS3; OUTPUT OUT=DIAG P=PRED R=RESID; ID MSRMNT; TITLE 'GAUGE CAPABILITY STUDY'; TITLE2 'EXAMPLE 9-7 (MONTGOMERY PAGES 455-456)'; PROC PLOT DATA=DIAG VPERCENT=50; PLOT RESID*PART=MSRMNT / VREF=0; ************************************; *** VARIANCE COMPONENTS ANALYSIS ***; ************************************; PROC VARCOMP DATA=RRS METHOD=REML; CLASS PART ; MODEL RESPONSE = PART ; RUN;